Copper solutions
Copper Solutions

Network Cables
    Twisted pair cable (SSTP), 4 pairs, Cat 7
    Shielded twisted pair cable, Cat  6a, 4 pairs,         solid, FR-PVC
    Twisted pair cable (UTP), Cat 6, 4 pairs, solid
    Twisted pair cable (UTP), Cat 6, 4 pairs, solid,         LSZH
    Twisted pair cable (FTP), 4 pairs, category 6,         solid, PVC
    Shielded twisted pair cable (STP), 4 pairs, solid,         indoor, Cat 6, PVC
    Twisted pair cable (UTP), 4 pairs, Cat 6,         stranded, PVC
    Unshielded twisted pair cable (UTP), cat 6, 4                pairs, solid, outdoor
    Shielded twisted pair cable (STP), cat 6, 4 pairs,         solid, outdoor
    Twisted pair cable UTP, cat 5e, 4 pairs, solid
    Twisted pair cable UTP, cat 5e, 4 pairs, solid         LSZH
    Twisted pair cable (UTP), cat 5e, 4 pairs, solid,         plenum
    Shielded twisted pair cable FTP, Cat 5e, 4 pairs,         solid
    Twisted pair cable UTP, 4 pairs, category 5e,         stranded (patch), PVC
    Unshielded twisted pair cable (UTP), 4 pairs,         solid, outdoor, Cat 5e
    Shielded twisted pair cable (STP), 4 pairs, solid,         outdoor, Cat 5e
    Unshielded twisted pair cable (UTP),        10/25/50/100 pairs, solid, indoor (Cat-3)
    Unshielded twisted pair cable (UTP),         10/25/50/100 pairs, solid, outdoor (Cat-3)
    Coaxial cable RG-6
    Coaxial cable RG-6CU
    Coaxial cable RG-11
    Coaxial cable RG-59
     Coaxial cable RG-59CU

Patch Panels
Keystone Jack
Connectors
Patch Cords
Faceplates
Cross Connection
Rack & Cable Manager Solutions
Data Center Solution
Fiber Solutions
Testers, Tools & Installation Equipment
 
Network Cables
TWISTED PAIR CABLE (SSTP), 4 PAIRS, CATEGORY 7
(1000 MHZ, 10GBE), SOLID, FR-LSZH

Description

Shielded Copper cable, 4 pairs, category 7a (1000 MHz, 10GbE), solid
4 separately foil-shielded pairs
General shield: wire braid
Cable is used for indoor installation

Specifications

Meets IEC 61156-5, IEC 61156-5 category 5e, 6, 7a requirements and ISO/IEC
11801 category 7a requirements
Fire protection – CM
The cable meets UL 1581 VW-1, IEC 60332-1 fire safety standard

Materials

Conductive material: wire made of soft annealed electrolytic copper
Conductor insulation: PE, film-porous-film structure
The cable jacket: FR-LSZH (low smoke zero halogen)
Shield: every pair is separately shielded with polyester aluminum foil (foil is outside), which covers 100% of twisted pair
General shield: tin Copper braid – 60% minimum

Technical characteristics

Conductor diameter: 0.57 mm (0.022") (23 AWG)
Outer cable diameter: 8.0 mm (0.4")
Insulation diameter: 1.43 (0.06")
Min. bend radius: 80 mm (3.15")
Operating temperature: -40°C – +70°C (-40°F – +158°F)
Weight per 1000 ft (304.8 m): 22.3 kg (49.1 lbs)
Standard package: 500 m (1640 ft)

 
 
 
  Terms and Conditions
  Copyright © 2015 NETX TELESYS UK LTD